Permits Index
39
Permits, 24 months
122 on record
100
Roofing permits
Sep 25, 2026
Last permit issued
95
Addresses with a page

Roofing: 100 permits

From Jan 14, 2020 to Sep 25, 2026. Across 23 roofing permits since October 5, 2024, most declared values run from $2,600 to $30,432 (the middle 80%); the median is $5,000 and half fall between $3,500 and $6,300. The lowest on record is $1,600 and the highest $99,129.

Since October 5, 2024, 24 listed below. Earlier permits, 76, are on their house pages: 2024: 12 · 2023: 21 · 2022: 21 · 2021: 6 · 2020: 16.

IssuedWorkBuildingDeclared valueContractor as filedPermit
Sep 25, 2026Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over new solid sheathing 45 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2BDwelling - Single Family$13,500—26016-90000-26374
Sep 15, 2026Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over new solid sheathing 20 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2BDwelling - Single Family$6,000—26016-90000-25090
Sep 14, 2026Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roofing Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2BDwelling - Single Family$18,000—26016-20000-24790
Aug 12, 2026Bldg-Alter/Repair: CONVERT GARAGE AND CARPORT INTO A DETACHED ACCESSORY DWELLING UNIT PER GC 66323 , REFRAME ROOF ALL WORK PER ENGAccessory Dwelling Unit$50,000—26016-20000-17897
Jul 27, 2026Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 22 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2BDwelling - Single Family$4,400—26016-90000-19813
Jul 20, 2026Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 25 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2BDwelling - Single Family$5,000—26016-90000-19123
Jul 15, 2026Bldg-Alter/Repair: SUPPLEMENTAL PERMIT OT 22014-20000-04444 TO REVISE ROOF FRAMING FOR PORTION OF SFD. REVISE FLOOR PLAN. REVISE FRAMING AND FOUNDATION PLANSDwelling - Single Family$3,000—22014-20001-04444
Jun 8, 2026Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 16 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2BDwelling - Single Family$3,200—26016-90000-15137
Mar 30, 2026Bldg-Alter/Repair: ePlan: Deferred submittal 25014-20000-01037 for approval of Roof TrussesDwelling - Single Family$2,500—25014-20002-01037
Mar 20, 2026Bldg-Alter/Repair: ePlan SUPPLEMENTAL TO 25010-20000-05399 TO REMOVE TRELLIS AND UPDATE ROOFING MATERIALAccessory Dwelling Unit——25010-20001-05399
Mar 10, 2026Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 22 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2BDwelling - Single Family$4,400—26016-90000-06375
Mar 2, 2026Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 24 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2BDwelling - Single Family$4,800—26016-90000-05509
Jan 16, 2026Bldg-Alter/Repair: Application of an approved coating to an existing roofApartment$99,129—26016-40000-01458
Dec 5, 2025Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 26 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2BDwelling - Single Family$5,200—25016-90000-35736
Oct 31, 2025Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 33 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2BDwelling - Single Family$6,600—25016-90000-32693
Oct 17, 2025Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 17 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2BDwelling - Single Family$3,400—25016-90000-31042
Sep 29, 2025Bldg-Alter/Repair: Application of an approved coating to an existing roofCondo-Multi Family$2,000—25016-40000-29201
Sep 11, 2025Bldg-Alter/Repair: INTERIOR REMODEL TO REMOVE 5/8" GYP BD AND REPLACE WITH 1-HOUR FIRE RATED, STC 50 SOUNDPROOF WALL WITH INSULATION TO EXTEND TO ATTIC ROOFDwelling - Single Family$1,600—25016-20000-27493
Jul 20, 2025Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 28 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2BDwelling - Single Family$5,600—25016-90000-22306
Jul 5, 2025Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 25 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2BDwelling - Single Family$5,000—25016-90000-20992
Jan 25, 2025Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 18 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2BDwelling - Single Family$3,600—25016-90000-02189
Oct 25, 2024Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 22 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2B.2 bathroom .Bathroom remodel for residential buildings .Replace drywall for single family dwellings and duplexes only.Kitchen remodel for residential buildingsDwelling - Single Family$33,540—24016-90000-34241
Oct 17, 2024Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 28 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2BDwelling - Single Family$5,600—24016-90000-33224
Oct 14, 2024Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 23 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2BDwelling - Single Family$4,600—24016-90000-32828

Heating and cooling: 17 permits

From May 8, 2020 to Sep 15, 2026. Across 14 heating and cooling permits since October 5, 2024, most declared values run from $895 to $50,115 (the middle 80%); the median is $8,248 and half fall between $3,187 and $17,500. The lowest on record is $501 and the highest $74,400.

Since October 5, 2024, 14 listed below. Earlier permits, 3, are on their house pages: 2023: 1 · 2020: 2.

IssuedWorkBuildingDeclared valueContractor as filedPermit
Sep 15, 2026Bldg-Alter/Repair: Window change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council , is required for doors and windows replaced in all residential buildings, three stories or less, per Section 150.2 1B of Title 24Apartment$7,146—26016-20000-24935
Aug 3, 2026Bldg-Alter/Repair: 1 door . Window and door change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council , is required for doors and windows replaced in all residential buildings, three stories or less, per Title 24, Part 6, Section 150.2 1BDwelling - Single Family$501—26016-90000-20441
Jul 9, 2026Bldg-Alter/Repair: 3 window . Window and door change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council , is required for doors and windows replaced in all residential buildings, three stories or less, per Title 24, Part 6, Section 150.2 1B.Replace existing siding with new stucco for single family dwellings and duplex only. Area = 472 sqft.3 door . Window and door change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council , is required for doors and windows replaced in all residential buildings, three stories or less, per Title 24, Part 6, Section 150.2 1BGarage - Private$2,916—26016-90000-18144
Jun 1, 2026Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over new solid sheathing 170 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2B.9 window . Window and door change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council , is required for doors and windows replaced in all residential buildings, three stories or less, per Title 24, Part 6, Section 150.2 1B.Replace drywall for single family dwellings and duplexes onlyDwelling - Single Family$54,450—26016-90000-14483
Nov 4, 2025Bldg-Alter/Repair: ePlan: SUPPLEMENTAL TO PERMIT 24014-20000-04272 TO REVISE TITLE 24 ANALYSIS FROM MINI-SPLIT A/C TO CENTRAL A/CAccessory Dwelling Unit$1,000—24014-20001-04272
Jun 24, 2025Bldg-Alter/Repair: 5 window . Window and door change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council , is required for doors and windows replaced in all residential buildings, three stories or less, per Title 24, Part 6, Section 150.2 1B.Re-stucco for residential buildings. Area = 200 sqft.5 bathroom .Bathroom remodel for residential buildings .Replace drywall for single family dwellings and duplexes onlyDwelling - Single Family$4,490—25016-90000-20077
Jan 28, 2025Bldg-Alter/Repair: Supplemental permit to 25016 - 90000 - 00832 to revise work description to read:Window and door change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council , is required for doors and windows replaced in all residential buildings, three stories or less, per Title 24, Part 6, Section 150.2 1BDwelling - Single Family$40,000—25016-20001-00832
Jan 23, 2025Bldg-Alter/Repair: 16 window . Window and door change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council , is required for doors and windows replaced in all residential buildings, three stories or less, per Title 24, Part 6, Section 150.2 1BDwelling - Single Family$4,000—25016-90000-02067
Jan 14, 2025Bldg-Alter/Repair: SUPPLEMENTAL PERMIT TO #25016-20000-00659 TO ADD: Window change-out (same size & type) for residential buildings. Dual glazing, labeledand certified by National Fenestration Rating Council , is required for doors and windowsreplaced in all residential buildings, three stories or less, per Title 24, Part 6, Section 150.2 1B. "COMPLY WITH DEPARTMENT ORDER effective date 04/12/2022. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"Apartment$850—25016-20001-00659
Jan 13, 2025Bldg-Alter/Repair: 12 window . Window and door change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council , is required for doors and windows replaced in all residential buildings, three stories or less, per Title 24, Part 6, Section 150.2 1B.1 bathroom .Bathroom remodel for residential buildings .Kitchen remodel for residential buildingsDwelling - Single Family$74,400—25016-90000-00832
Jan 10, 2025Bldg-Alter/Repair: Window change-out (same size & type) for residential buildings. Dual glazing, labeledand certified by National Fenestration Rating Council , is required for doors and windowsreplaced in all residential buildings, three stories or less, per Title 24, Part 6, Section 150.2 1BApartment$9,350—25016-20000-00659
Oct 28, 2024Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 20 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2B.9 window . Window and door change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council , is required for doors and windows replaced in all residential buildings, three stories or less, per Title 24, Part 6, Section 150.2 1B.1 bathroom .Bathroom remodel for residential buildings .Kitchen remodel for residential buildingsDwelling - Single Family$17,750—24016-90000-34429
Oct 25, 2024Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 22 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2B.13 window . Window and door change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council , is required for doors and windows replaced in all residential buildings, three stories or less, per Title 24, Part 6, Section 150.2 1B.2 bathroom .Bathroom remodel for residential buildings .Kitchen remodel for residential buildingsDwelling - Single Family$16,750—24016-90000-34244
Oct 24, 2024Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 22 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2B.9 window . Window and door change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council , is required for doors and windows replaced in all residential buildings, three stories or less, per Title 24, Part 6, Section 150.2 1B.Replace existing siding with new stucco for single family dwellings and duplex only. Area = 184 sqft.Replace drywall for single family dwellings and duplexes onlyDwelling - Single Family$14,882—24016-90000-34036

Electrical: 2 permits

From Feb 15, 2024 to Sep 29, 2025. Fewer than 5 electrical permits since October 5, 2024 carry a declared value, so no range is computed; the rows are below.

Since October 5, 2024, 1 listed below. Earlier permits, 1, are on their house pages: 2024: 1.

IssuedWorkBuildingDeclared valueContractor as filedPermit
Sep 29, 2025Nonbldg-Alter/Repair: Re-plaster existing swimming pool (a separate express mechanical permit for new skimmer and a separate express electrical permit for new pool luminaire is required, when applicable, except for one and two-family dwellings)Pool/Spa - Private$10,000—25026-20000-00163

Plumbing: 2 permits

From Jan 24, 2020 to Mar 16, 2020. Fewer than 5 plumbing permits since October 5, 2024 carry a declared value, so no range is computed; the rows are below.

Since October 5, 2024, 0 listed below. Earlier permits, 2, are on their house pages: 2020: 2.

IssuedWorkBuildingDeclared valueContractor as filedPermit

Solar: 1 permit

From Jul 1, 2020 to Jul 1, 2020. Fewer than 5 solar permits since October 5, 2024 carry a declared value, so no range is computed; the rows are below.

Since October 5, 2024, 0 listed below. Earlier permits, 1, are on their house pages: 2020: 1.

IssuedWorkBuildingDeclared valueContractor as filedPermit

Addresses on this street with a page

Source

Los Angeles Department of Building and Safety, via the city open-data portal, pulled nightly. As of October 5, 2026. Storm dates touching this street will appear here once the hail record is attached.