S Motor Ave, Los Angeles: permits on record
49 home-service permits on record on S Motor Ave since February 14, 2020, 23 of them since October 3, 2024, at 42 addresses. Home-service permits only (roofing, heating and cooling, solar, electrical, plumbing, water heaters); other building permits are kept in the record and not shown. Permits are listed without house numbers; each address has its own page below.
Roofing: 41 permits
From Mar 9, 2020 to Aug 19, 2026. Across 20 roofing permits since October 3, 2024, most declared values run from $4,900 to $48,400 (the middle 80%); the median is $11,700 and half fall between $6,700 and $21,250. The lowest on record is $1,200 and the highest $200,000.
Since October 3, 2024, 20 listed below. Earlier permits, 21, are on their house pages: 2024: 6 · 2023: 5 · 2022: 4 · 2021: 2 · 2020: 4.
| Issued | Work | Building | Declared value | Contractor as filed | Permit |
|---|---|---|---|---|---|
| Aug 19, 2026 | Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over new solid sheathing 50 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2B | School Building | $15,000 | — | 26016-90000-22068 |
| Jun 11, 2026 | Bldg-Alter/Repair: EPLAN REMODEL 2-STORY SFD WITH NEW ROOF DECK PER ENGINEER DESIGNNO SQFT ADDED | Dwelling - Single Family | $200,000 | — | 25016-10000-19837 |
| Apr 30, 2026 | Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over new solid sheathing 49 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2B | Dwelling - Single Family | $14,700 | — | 26016-90000-11511 |
| Apr 23, 2026 | Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 38 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2B | Church | $7,600 | — | 26016-90000-10741 |
| Mar 27, 2026 | Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 100 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2B | School Building | $20,000 | — | 26016-90000-08302 |
| Mar 27, 2026 | Bldg-Alter/Repair: Application of an approved coating to an existing roof | Retail | $25,000 | — | 26016-20000-08248 |
| Feb 3, 2026 | Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over new solid sheathing 24 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2B | Dwelling - Single Family | $7,200 | — | 26016-90000-03224 |
| Feb 3, 2026 | Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing __220__Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2B | Apartment | $46,000 | — | 26016-70000-03180 |
| Aug 22, 2025 | Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. overexisting solid sheathing Squares. Class A roof covering is required within Very High FireHazard Severity Zone . For residential roof replacement > 50% of the total roofarea, apply Cool Roof Product labeled and certified by Cool Roofing Rating Council .Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section141.0 2B | Office | $5,250 | — | 25016-20000-25500 |
| Jun 27, 2025 | Bldg-Alter/Repair: Re-roof with Class A or B material weighing less than 6 pounds per sq. ft. over existing solid sheathing__26____Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone .For residential roof replacement>50% of the total roof area, apply Cool Roof Product labeled and certified byCool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part6, Section 141 2B | Office | $12,000 | — | 25016-40000-20374 |
| Jun 27, 2025 | Bldg-Alter/Repair: Re-roof with Class A or B material weighing less than 6 pounds per sq. ft. over existing solid sheathing___9___Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone .For residential roof replacement>50% of the total roof area, apply Cool Roof Product labeled and certified byCool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part6, Section 141 2B | Office | $5,000 | — | 25016-10000-20387 |
| Jun 25, 2025 | Bldg-Alter/Repair: Re-roof with Class A or B material weighing less than 6 pounds per sq. ft. over new solid sheathing25_Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . Forresidential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6,Section 141 2B | Dwelling - Single Family | $25,000 | — | 25016-30000-20115 |
| Jun 11, 2025 | Bldg-Alter/Repair: UPGRADE 1 BATHROOM TO BE DAS COMPIANCE AND FIRE DAMAGE REPAIR TO ROOF TO 1 STORY OFFICE/RETAIL/STORAGE PER ENGINEERING - NO CHANGE IN PARKING | Retail | $70,000 | — | 24016-20000-32515 |
| Jun 10, 2025 | Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 32 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2B | Retail Store or Business | $6,400 | — | 25016-90000-18660 |
| May 1, 2025 | Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 95 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2B | Miscellaneous Bldg/Structure | $19,000 | — | 25016-90000-14139 |
| Mar 20, 2025 | Bldg-Alter/Repair: Re-roof with Class A or B material weighing less than 6 pounds per sq. ft. over existing solid sheathing_23_Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone .For residential roof replacement>50% of the total roof area, apply Cool Roof Product labeled and certified byCool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part6, Section 141 2B | Dwelling - Single Family | $6,800 | — | 25016-30000-08081 |
| Feb 10, 2025 | Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 6 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2B | Dwelling - Single Family | $1,200 | — | 25016-90000-03622 |
| Jan 20, 2025 | Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over new solid sheathing 35 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2B | Dwelling - Single Family | $10,500 | — | 25016-90000-01520 |
| Oct 29, 2024 | Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 20 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2B | Dwelling - Single Family | $4,000 | — | 24016-90000-34599 |
| Oct 9, 2024 | Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over new solid sheathing 38 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2B | Dwelling - Single Family | $11,400 | — | 24016-90000-32373 |
Heating and cooling: 3 permits
From Apr 26, 2021 to Jul 30, 2025. Fewer than 5 heating and cooling permits since October 3, 2024 carry a declared value, so no range is computed; the rows are below.
Since October 3, 2024, 1 listed below. Earlier permits, 2, are on their house pages: 2022: 1 · 2021: 1.
| Issued | Work | Building | Declared value | Contractor as filed | Permit |
|---|---|---|---|---|---|
| Jul 30, 2025 | Bldg-Alter/Repair: 13 Window and 2 door change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council , is required for doors and windows replaced in all residential buildings, three stories or less, per Section 150.2 1B of Title 24 | Dwelling - Single Family | $33,611 | — | 25016-10000-23293 |
Electrical: 2 permits
From Jan 19, 2021 to Jan 23, 2026. Fewer than 5 electrical permits since October 3, 2024 carry a declared value, so no range is computed; the rows are below.
Since October 3, 2024, 1 listed below. Earlier permits, 1, are on their house pages: 2021: 1.
| Issued | Work | Building | Declared value | Contractor as filed | Permit |
|---|---|---|---|---|---|
| Jan 23, 2026 | Bldg-Alter/Repair: Re-plaster existing swimming pool (a separate express mechanical permit for new skimmer and a separate express electrical permit for new pool luminaire is required, when applicable, except for one and two family dwelling) | School Building | $20,000 | — | 26016-90000-02192 |
Plumbing: 2 permits
From Feb 14, 2020 to May 21, 2020. Fewer than 5 plumbing permits since October 3, 2024 carry a declared value, so no range is computed; the rows are below.
Since October 3, 2024, 0 listed below. Earlier permits, 2, are on their house pages: 2020: 2.
| Issued | Work | Building | Declared value | Contractor as filed | Permit |
|---|
Solar: 1 permit
From Jun 16, 2026 to Jun 16, 2026. Fewer than 5 solar permits since October 3, 2024 carry a declared value, so no range is computed; the rows are below.
| Issued | Work | Building | Declared value | Contractor as filed | Permit |
|---|---|---|---|---|---|
| Jun 16, 2026 | Bldg-Alter/Repair: Eplan: Installation of solar pv on rooftop of commercial building | Health Club | $25,000 | — | 26016-10000-09337 |
Addresses on this street with a page
Source
Los Angeles Department of Building and Safety, via the city open-data portal, pulled nightly. As of October 3, 2026. Storm dates touching this street will appear here once the hail record is attached.