W Maryland Dr, Los Angeles: permits on record
25 home-service permits on record on W Maryland Dr since March 2, 2020, 8 of them since October 6, 2024, at 24 addresses. Home-service permits only (roofing, heating and cooling, solar, electrical, plumbing, water heaters); other building permits are kept in the record and not shown. Permits are listed without house numbers; each address has its own page below.
Roofing: 20 permits
From Nov 10, 2020 to Sep 16, 2026. Across 6 roofing permits since October 6, 2024, most declared values run from $2,400 to $26,117 (the middle 80%); the median is $5,450 and half fall between $3,850 and $10,900. The lowest on record is $1,000 and the highest $40,000.
Since October 6, 2024, 7 listed below. Earlier permits, 13, are on their house pages: 2024: 1 · 2023: 4 · 2022: 2 · 2021: 3 · 2020: 3.
| Issued | Work | Building | Declared value | Contractor as filed | Permit |
|---|---|---|---|---|---|
| Sep 16, 2026 | Bldg-Alter/Repair: Re-roof with Class A or B material weighing less than 6 pounds per sq. ft. over existing solid sheathing __21____Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2B | Dwelling - Single Family | $12,233 | — | 26016-10000-25115 |
| Aug 19, 2026 | Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 20 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2B | Dwelling - Single Family | $4,000 | — | 26016-90000-22044 |
| Apr 21, 2026 | Bldg-Alter/Repair: SUPPLEMENTAL TO PERMIT #26016-90000-09072 TO CHANGE WOEK DESCRIPTION FROM OVER EXISTING SHEATHING TO NOW READ Re-roof with Class A or B material weighing less than 6 pounds per sq. ft. over new solid sheathing___19___Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . Forresidential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by CoolRoof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6,Section 141 2B | Dwelling - Single Family | — | — | 26016-10001-09072 |
| Apr 7, 2026 | Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 19 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2B | Dwelling - Single Family | $3,800 | — | 26016-90000-09072 |
| Nov 20, 2025 | Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over new solid sheathing 23 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2B | Dwelling - Single Family | $6,900 | — | 25016-90000-34328 |
| Jun 17, 2025 | Bldg-Alter/Repair: Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 5 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2B | Garage - Private | $1,000 | — | 25016-90000-19427 |
| Dec 9, 2024 | Bldg-Alter/Repair: Re-roof with Class A or B material weighing less than 6 pounds per sq. ft. over existing solid sheathing 22 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone . For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council . Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0 2B | Dwelling - Single Family | $40,000 | — | 24016-10000-37489 |
Heating and cooling: 2 permits
From Mar 2, 2020 to Jun 24, 2026. Fewer than 5 heating and cooling permits since October 6, 2024 carry a declared value, so no range is computed; the rows are below.
Since October 6, 2024, 1 listed below. Earlier permits, 1, are on their house pages: 2020: 1.
| Issued | Work | Building | Declared value | Contractor as filed | Permit |
|---|---|---|---|---|---|
| Jun 24, 2026 | Bldg-Alter/Repair: 4 window . Window and door change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council , is required for doors and windows replaced in all residential buildings, three stories or less, per Title 24, Part 6, Section 150.2 1B.1 door . Window and door change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council , is required for doors and windows replaced in all residential buildings, three stories or less, per Title 24, Part 6, Section 150.2 1B | Dwelling - Single Family | $1,501 | — | 26016-90000-16689 |
Plumbing: 2 permits
From Dec 6, 2021 to Sep 29, 2022. Fewer than 5 plumbing permits since October 6, 2024 carry a declared value, so no range is computed; the rows are below.
Since October 6, 2024, 0 listed below. Earlier permits, 2, are on their house pages: 2022: 1 · 2021: 1.
| Issued | Work | Building | Declared value | Contractor as filed | Permit |
|---|
Electrical: 1 permit
From Dec 3, 2021 to Dec 3, 2021. Fewer than 5 electrical permits since October 6, 2024 carry a declared value, so no range is computed; the rows are below.
Since October 6, 2024, 0 listed below. Earlier permits, 1, are on their house pages: 2021: 1.
| Issued | Work | Building | Declared value | Contractor as filed | Permit |
|---|
Addresses on this street with a page
Source
Los Angeles Department of Building and Safety, via the city open-data portal, pulled nightly. As of October 6, 2026. Storm dates touching this street will appear here once the hail record is attached.